50000 kg hr of saturated steam feed water enters the boiler
_steam_boiler.jpg)
SZS series gas-fired (oil-fired) steam boiler
SZS series boiler is designed with longitudinal double drums and " D " type chamber structure. Furnace is placed on the right and convection tube bank is on the left, super heater is arranged at convection tube bank. The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways. Around the furnace is membrane water cooling tube wall. Furnace and tube bank are totally separated by the membrane water tube cooling wall at the left side of the furnace.
Email:kathy@zozen.com
Send Inquiry
DHL series biomass-fired steam boiler
DHL corner tube boiler is field assembled boiler, it uses a piping system as the frame of the entire boiler, and it bears the full load of the boiler, which makes a non-framework boiler. At the same time, this frame also serves as the down comer of the boiler and upper and lower headers. The boiler drum is an external type drum, the furnace is a fully enclosed membrane wall structure, the convective heat absorbing surface adopts the flag tube structure.
Email:kathy@zozen.com
Send Inquiry
CFB (circulating fluidized bed) coal fired steam boiler
As a new mature high-efficiency and low-pollution clean coal technology, circulating fluidized bed combustion (CFBC) technology has many advantages that other combustion methods do not have. Circulating fluidized bed combustion is low-temperature combustion, so the NOx emission is much lower than that of pulverized coal furnace, only 200ppm. CFBC can desulfurize directly during the combustion process, and the desulfurization efficiency is high.
Email:kathy@zozen.com
Send Inquiry
RYQ series molten salt heater
Molten salt heaters use molten potassium nitrate and sodium nitrite as heating media. Molten salt heater will heat the powder salt over the melting point until the viscosity of the molten salt allows circulating pump works, after the whole system is under circulating condition, then feed then into the thermal oil heater for further circulating rising temperature to make it to be recycling used. Normal media working temperature is 400-550℃, top working temperature could reach 600℃.
Email:kathy@zozen.com
Send InquirySteam Calculators: Boiler Calculator
(Saturated Liquid) Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.
Read MoreSteam produced heat transfer heat exchangers | Physics Forums
Feb 18, 2016· Dry saturated steam at a temperature of 180oC is to be produced in a fire tube boiler from the cooling of 50 000 kg h–1 of flue gases from a pressurised combustion process. The gases enter the tubes of the boiler at 1600oC and leave at 200oC. The feed water is externally preheated to 180oC before entering the boiler.
Read MoreSolved: Saturated steam is generated in a boiler by
Saturated steam is generated in a boiler by converting a saturated liquid to a saturated vapor at 200 psia. This is done by transferring heat from the combustion gases, which are at 500°F, to the water in the boiler tubes. Calculate the wasted work potential associated with this heat transfer process.
Read MoreCalculator: Saturated Steam Table by Pressure | TLV - A
Online calculator with Saturated Steam Table by Pressure. Includes 53 different calculations. Equations displayed for easy reference.
Read MoreChange in enthalpy can occur because of
•Steam at a rate of 100 kg/h is used to heat a stream of gas flowing on the tube side of a heat exchanger. The steam enters the shell side of the heat exchanger as saturated vapor at 10 bar of 90% quality, and exits as saturated liquid water at 10 bar. Calculate the rate of heat transfer to the gas side.
Read MoreSolved: 3. (a) Dry Saturated Steam At A Temperature Of 180
3. (a) Dry saturated steam at a temperature of 180°C is to be produced in a fire tube boiler from the cooling of 50000 kg h- of flue gases from a pressurised combustion process. The gases enter the tubes of the boiler at 1600'C and leave at 200'C.
Read MoreBoiler Capacity - Engineering ToolBox
Boiler load - the capacity of a steam boiler - is often rated as boiler horse powers, lbs of steam delivered per hour, or BTU. Lbs Steam delivered per Hour Large boiler capacities are often given in lbs of steam evaporated per hour under specified steam conditions.
Read MoreConverting Boiler steam rating from Kg/hr to Liters of
Re: Converting Boiler steam rating from Kg/hr to Liters of water capacity Thanks for the reply The boiler is a industrial steam boiler, which uses the steam for the process on site ( brewing boooz ) in this case in the past I have always been given the steam rating in LB/HR and have used the following;
Read MoreSteam produced per hour | Physics Forums
Nov 14, 2014· Dry saturated steam at a temperature of 180ºC is to be produced in a fire tube boiler from cooling of 50000 kg/h of flue gases from a pressurised combustion process. The gases enter the tubes of the boiler at 1500ºC and leave at 100ºC. The feed water is externally preheated to 180ºC before entering the boiler.
Read More1143 Boiler efficiency This is the ratio of heat actually
If a boiler consisting of an economiser and superheater is considered to be a single unit, then the efficiency is termed as overall efficiency of the boiler. Example 11.1 A boiler evaporates 3.6 kg of water per kg coal into dry saturated steam at 10 bar.
Read More